Powercon is well-known for it's quality products and ability to
produce standard switchgear, customized switchgear, and specialized
control systems to meet specific requirements. Follow the links
below for more information on specific products.
| Metal Clad Switchgear » |
| | Powercon's advanced Metal Clad Switchgear line is completely factory-built and wired. Each cubicle
may contain the circuit breaker, bus bars, primary
and secondary disconnecting devices, instrument
transformers, instruments and relays, secondary
wiring and more. The switchgear is
designed so that additional circuit breakers or
auxiliary cubicles may be added in the future.Learn More... |
| |
| Metal-Enclosed Interrupter Switchgear (MEIS) » |
| | Powercon's MEIS Switchgear exceeds ANSI/IEEE Standard C37.20.3, with no exceptions taken to any requirement of the ANSI/IEEE.
These switches are available with either electrical or
mechanical operators. When used in conjunction with fuses they
will afford overload, short circuit and disconnect services. This switchgear is used:
- On the primary of transformers for their protection and isolation.
- For the protection and isolation of single circuit systems.
- For the protection and isolation of multi-circuit systems.
- For automatic transfer schemes where their ratings are not exceeded.
Learn More... |
| |
| Metal-Enclosed Bus Systems » |
| | Powercon offers our customers complete system integration and responsibility. We also manufacture 5kV-38kV Bus Duct which can connect various line-ups of switchgear together or can be used as a connection between Powercon Switchgear and power transformers as shown. Our Bus Duct has been designed tested to verify compliance to A.N.S.I. Standards. Learn More... |
| |
| Climatized Enclosures » |
| | The PowerControl Complex may be installed in many environments - deserts where the temperature may rise as high as 135°F with humidity of 90% or in cold areas where the temperature may go as low as -40°F. Recently, more complex requirements have included refrigerators, work benches, water fountains, fire detection systems, spare parts storage, emergency lighting, and necessary alarms in case of failures. Seismic requirements for the completely assembled units are now under consideration. Learn More... |
| |
| Power System Grounding Equipment » |
| | Powercon's high resistance grounded neutral system with traceable signal to fault, is one in which a high-value resistor has been inserted in the neutral connection to ground to limit the resistor current under ground-fault conditions to a value not less than the total system charging current, resulting in a total ground fault current of approximately the square root of 2 times the charging current. Learn More... |
| |
| Key Interlock Systems » |
| | An interlock system is a series of key interlocks applied to associated equipment in such a manner as to allow operation of the equipment only in a prearranged sequence. Interlocks are applicable to practically any field wherein human life or property is endangered, by an improper operation or improper sequence of operations.
The Powercon Key Interlock System is a simple, easy method of applying individual key interlock units and assemblies to electrical switchgear assemblies requiring operation in predetermined sequence.
Learn More... |
| |
| Vertical Lift Breakers » |
| | Replacement vacuum breakers AND switchgear for GE Magne-Blast equipment.
Match and line-up to existing equipment WITHOUT transition sections AND maintain breaker interchangeability. Learn More... |
| |